Description:It is a multifunction time delay relay module.LCD display, very clear, easy to use, powerful.It can be widely used at Smart home,Industrial control,Automatic irrigation,Indoor ventilati...
$5.98
$5.98
  customers are viewing this product

Description:

It is a multifunction time delay relay module.LCD display, very clear, easy to use, powerful.It can be widely used at Smart home,Industrial control,Automatic irrigation,Indoor ventilation.Protection equipment.

Features:

1.LED display;

2.Support high and low level trigger;

3.Emergency stop function;

4.Sleep mode,Wake up with any button;

5.Automatically save parameters;

6.Support UART Set;

7.Independent of parameters;

8.Continuously adjustable from 0.1 seconds to 9999 minutes;

9.Optocoupler isolation.Enhanced anti-jamming capability

 Specifications

1.Product Name:Delay Relay Module

2.Product Number:XY-LJ02

3.Working Voltage:DC 6V-30V or 5V Micro USB

4.Control Current:10A(Max)

5.Quiescent Current:15mA

6.Working Current:50mA

7.Working temperature: -40~85℃

8.Suitable for battery:Storage Battery,Lithium battery

9.Trigger signal source: High level trigger (3.0V~24V), Low level trigger (0.0V~0.2V), switching control (passive switch)

10.Reverse protection:Yes

11.Physical dimension:80*38*2.1mm

Work Mode:

P1:Relay will keep ON for time OP after get trigger signal and then relay OFF;The input signal is invalid if get trigger signal again during delay time OP.

P2:Relay will keep ON for time OP after get trigger signal and then relay OFF;Module will restart delay if get trigger signal again during delay time OP.

P3:Relay will keep ON for time OP after get trigger signal and then relay OFF;Module will reset and stop timing if get trigger signal again during delay time OP.

P4:Relay will keep OFF for time CL after get trigger signal and then relay keep ON for time OP and then relay will OFF.

P5:Relay will keep ON for time OP after get trigger signal and then relay keep OFF for time CL and then loops the above action.Module will reset and stop timing and relay OFF if get trigger signal again during loops.The number of cycles (LOP) can be set.

P6:Relay will keep ON for time OP after power on without get trigger signal and then relay keep OFF for time CL and then loops the above action.The number of cycles (LOP) can be set.

P7:Signal hold function.Reset delay time and relay keep ON if keep get trigger signal.Relay OFF when the signal disappears.Reset delay time when get trigger signal again during timing.

Timing range:

Continuously adjustable from 0.01 seconds to 9999 minutes.

Enter the settings interface when short press button ‘STOP’ in the OP / CL parameter modification interface(Flashing) to select timing range.

Pay attention to the position where the decimal point moves when the button is pressed.

Display ‘XXXX’.No decimal point, the timing range is 1 second ~ 9999 seconds.

Display ‘XXX.X’.The decimal point is the penultimate, timing range is 0.1 second to 999.9 seconds.

Display ‘XX.XX’.The decimal point is the third last, timing range is 0.01 second to 99.99 seconds.

Display ‘X.X.X.X’.The decimal point is fully lit, timing range is 1 minute to 9999 minutes.

For example, if you want to set the OP to 3.2 seconds, move the decimal point to the penultimate position, LCD will display ‘003.2’.

Parameter Description:

OP: Turn On time;

CL: Turn OFF time;

LOP: Number of cycles.Range is 1-9999tims.’----’ means unlimited loop.

7.Set Parameter:

Long press:keep press button for more than 3second.

1.Enter set parameter menu by long press button 'SET'.

2.Work mode will flash at first set the working mode.Short press the UP/DOWN button to set the working mode.

3.Short press the SET button to select the working mode and enter the system parameter settings.

4.In the system parameter setting interface, short press the ‘SET’ button to switch the system parameters to be modified, short/long press the UP/DOWN button to modify value;

Note:Short press ‘SET ’ is invalid at mode P1,P2,P3,P7.

5.Enter setting interface when short press button ‘STOP’ in the OP/CL parameter modification interface(Flashing) to select timing range (1s/0.1s/0.01s/1min).

6.Save the parameter settings and exit the settings interface when long press ‘SET’ button after all the parameters are set.

UART communication and parameter settings

The system supports UART data upload and parameter setting functions (TTL level);

UART: 9600, 8, 1

NO.

Command

Function

1

Read

Read the parameter setting

2

OP:XXXX

Set the minimum delay time for turn ON : 1s

3

OP:XXX.X

Set the minimum delay time for turn ON : 0.1s

4

OP:XX.XX

Set the minimum delay time for turn ON : 0.01s

5

OP:X.X.X.X

Set the minimum delay time for turn ON : 1min

6

CL:XXXX

Set the minimum delay time for turn OFF : 1s

7

CL:XXX.X

Set the minimum delay time for turn OFF : 0.1s

8

CL:XX.XX

Set the minimum delay time for turn OFF : 0.01s

9

CL:X.X.X.X

Set the minimum delay time for turn OFF : 1min

10

LP:XXXX

Number of cycles:1-9999

11

ON

Relays Enable

12

OFF

Relays Disable

13

PX

Set mode P1~P7

 

Application:

1. Motor

2. Robot

3. Smart home

4. Industrial control

5. Automatic irrigation

6. Indoor ventilation

Additional Features:

1.Auto sleep function: Long press button 'STOP' in the normal running interface to turn on or off auto sleep function.

L-P:ON,Turn ON auto sleep function.

L-P:OFF,Turn OFF auto sleep function.

2.Relay function selection:Short press button 'STOP' in the normal running interface to turn on or off relay delay function.

'ON':Relay is normally turned on when the conduction condition is met.

'OFF':Relay is normally turned off even though the conduction condition is met.

LCD will flashes 'OUT' at status of OFF.

3.View parameters: In the running interface, short press the SET button to display the current parameter settings of the system, which does not affect the normal operation of the system.

4.Switch the display content: It will switch the display content by short press button 'DOWN' in the P5 or P6 mode

Package Included:
1 x 1 Channel 5V Relay Module Time Delay Relay Module Trigger Switch Timing Cycle

Manual / instructions NOT included, please see description

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the 'Complete Orders' link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

You have successfully subscribed!